Abstract

In this paper, voltage mode (VM) and current mode (CM) control are used for controlling the peak dc-link voltage of high-performance Z-source Inverter (ZSI), where the peak DC-link voltage is estimated by measuring the input and capacitor voltages. Both controllers are designed base on small signal model using Bode diagram. The performance of both control methods is verified by simulation of a 30 kW high-performance ZSI with inductive load during start-up, and with input voltage, reference voltage and load disturbances. Both methods have a comparable response during input voltage and reference voltage step, but the current mode control has a better response during start-up, steady state operation and load step with a reduced system order and a simpler controller.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.