Abstract

Two different methods for measuring the surface resistance of thin polymeric films are presented. The first method is the standard method and utilizes concentric ring metal electrodes. The second one is a novel method and uses instead concentric cylindrical metal electrodes. Both have been studied analytically and experimentally. The voltage distributions that are developed in both methods are calculated, plotted using three-dimensional graphs, and finally compared in order to analyze the advantages and disadvantages of the two measuring systems (acetate is the dielectric). The cylindrical electrodes, which give lower stresses around the outer electrode, seem to be more suitable for the measurements of the surface resistance of thin polymeric films.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.