Abstract

Stand-Alone Photovoltaic systems (SAP) based on power electronics converters have found high attention, recently. According to the rate of power, three phase inverter is more applicable for high power applications. However, unbalanced loading condition is inevitable condition for these inverters. To prepare a current flow for inevitable fourth wire current, 4-Leg inverter is a beneficial solution. To sinusoidal load voltage shaping, the control method is very important since it must maintain three-phase balanced sinusoidal load voltages. Among different linear and non-linear control methods, deadbeat (DB) method offers high simplicity as well as good accordance for digital implementation. But, it suffers from two sampling period delay which deteriorate the load voltages quality and sometimes, results in instability of the control system. In this paper, new DB control method with delay compensation strategy is proposed which not only have the usual benefits of the DB control method but also, it overcomes the aforementioned weakness. Finally, a 3kW laboratory test bench based on DSP-Based digital control board is provided to consider the result of the proposed control methods. Several tests under various inverter loads such as no load, full linear load and 100% unbalanced load are done to evaluate the benefits of the proposed system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call