Abstract

This paper proposes a new voltage control technique for IPMSM drives to extend DC-link voltage utilization for flux weakening operation. The presented method does not require look-up-table and motor parameter for flux weakening operation. The difference between the switching period and summation of active switching times for PWM control of inverter is used to modify the d-axis current reference under flux weakening region such that the voltage trajectory of inverter output can move to the hexagon of the space vector to extend the utilization of DC-link voltage. As the summation of active switching times is less than its switching period, constant torque with maximum torque per ampere (MPTA) control is retained. In contrast, flux weakening control is considered. Smooth and automatic transition between constant torque and flux weakening regions can be achieved. Experimental and simulation results will be presented to fully support the claims.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.