Abstract
We examine a technique for enhancing the voltage contrast (VC) of a failure analysis (FA) tool, defect review scanning electron microscope (DR-SEM). For an SRAM, we demonstrate a dependence of gate-leak VC on the relative angle (RA) between the direction of beam scanning by the FA tool and the lengthwise direction of the gate electrode. Experimental results show that better VC results are obtained when RA is zero, in other words, a beam's scan-line is parallel with the SRAM gate. We propose a simple qualitative resistor-capacitor model to explain this phenomenon. With the help of this VC enhancement technique of the FA tool, we could tune the electron beam inspection (EBI) recipe to an appropriate condition quicker. The cycle time of EBI recipe tuning was shortened from five to two days. As a result, correct EBI evaluation results of countermeasure experiments led us to a yield enhancement solution within a shorter period of time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.