Abstract

Volatile organic compounds (VOCs) emitted into headspace over discrete electronic components including resistors, capacitors, diodes, transistors, and transformers were identified and quantitatively determined in Part 1 of this series using gas chromatography/mass spectrometry. Vapors emissions of VOCs were characteristic of each component and headspace concentrations increased with temperature and persisted with time in most instances. Technology suitable for routine continuous monitoring of air quality based on gas chromatography/differential mobility spectrometry (GC/DMS) was evaluated with the same electronic components here, Part 2 of this series. Distinctive patterns in plots of ion peak intensity, retention time, and compensation voltage were obtained from VOCs from resistors, capacitors, and insulation from wires of a transformer held at 200°C for ten minutes. Intensity of response and analytically rich information produced by GC/DMS suggest further utility also as an air quality monitor or smart smoke alarm with electronics-dense habitats in spacecraft or offices and industrial venues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.