Abstract

High-power laser facilities, such as Laser MegaJoule, are currently being operated for inertial confinement fusion experiments. Emission of volatile organic compounds (VOC) and moreover semivolatile organic compounds (SVOCs) from seals in laser environment is of tremendous importance for the optics lifetime and laser performance. That is why all the seals were screening in the same conditions: 48 h at 30°C and three successive cycle of 1.5 h at 50°C. This paper focuses on the qualification test performed on three seals: two ethylene propylene diene monomer (EPDM) and one fluoropolymer (FPM). It is shown that the molded and the extruded EPDM do not outgas the same amount neither the same molecules whereas EPDM and FPM outgas nearly the same level of phthalates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.