Abstract

AbstractDetailed hydodynamic measurements have been obtained for fully cylindrical spout‐fluid beds of 1.3 mm, 1.8 mm and 2.5 mm glass beads in a fully cylindrical column of diameter 152 mm using three different types of optical fibre probes. The reallocation of up to 43% of the air to auxiliary air introduced through the conical base caused some decrease in spout voidages, but remarkably little change in spout diameter compared with spouted beds where there was no auxiliary air addition. Auxiliary air led also to some decrease in particle velocities in the spout and to a modest decrease in the net solids circulation rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.