Abstract

Motivated by recent research on two-phase flow void fraction measurement, this paper presents a study on void fraction measurements of a lubricant air-oil two-phase flow using a near infrared (NIR) optical-fiber spectrometer associated with partial least squares (PLS) regression models. To overcome the measurement inaccuracy due to interface scattering, this study used PLS regression models to analyse the spectrum of air-oil two-phase flow. First, an NIR optical-fiber spectrometer experimental system was developed. Second, a flow regime analysis was conducted for the bubble flow transition inside the experimental system. Finally, the PLS regression model validations, the void fraction measurement accuracies, and the uncertainties of the experimental system were evaluated and discussed, and the different PLS regression models were compared in detail. The results indicate that the NIR optical-fiber spectrometer combined with the PLS regression model can achieve void fraction measurements of lubricants in air-oil two-phase flow, with a maximum squared correlation coefficient (R 2) of 0.981, a minimum Type A uncertainty of 0.039% and a minimum expanded uncertainty of 0.077%.