Abstract
Void fraction measurement tests for BWR fuel assemblies have been conducted as part of a Japanese national project. The aim was to verify the current BWR void fraction prediction method. Void fraction was measured using an X-ray CT scanner. This paper describes typical results of void fraction distribution measurements and compares subchannel-averaged void fraction data with current subchannel analysis codes. The subchannel analysis codes COBRA/BWR and THERMIT-2 were used in this comparison. The agreement between data for an actual BWR fuel assembly with two unheated rods was good, but in the case of many unheated rods, the codes were unable to predict well large void fraction gradient in the radial direction observed in the measured data over the unheated rod region. The prediction errors of COBRA/BWR and THERMIT-2 for the subchannel-averaged void fraction were (A) (average of difference between measurement and calculation)=-1.1%. σ (standard deviation)=5.3% and <A>=-2.2%, σ=6.3 %, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.