Abstract

Impaction of foreign bodies in the esophagus is a frequent emergency in otorhinolaryngology. However, diagnosing and managing denture impaction in the esophagus presents greater challenges compared to other foreign bodies, often leading to various complications. This study reported a rare case of vocal cord immobility after the evacuation of denture impaction in the esophagus using lateral pharyngotomy. The patient, a 73-year-old man, experienced throat discomfort after swallowing a denture an hour before admission. According to the CT scan carried out, a 3.7 cm long denture was found around the T3-T5 spine level and was located 3 mm lateral right to the descendant aorta and 4 mm posterior of the trachea. During esophagoscopy extraction, the denture was stuck in the upper esophagus and was successfully evacuated by lateral pharyngotomy. Subsequently, the patient developed vocal cord immobility, and this case underscores the importance of considering vocal cord complications following the extraction of a denture impaction in the esophagus.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.