Abstract
The present paper discusses technical aspects of the vortex-induced vibrations (VIVs) of structures excited by the wind in the framework of the spectral model, which is applied by many codes and guidelines for civil engineering verifications. Quantitative thresholds related to Scruton number domains, where the structural response can be considered in “forced vibration” or “lock-in” regime, are proposed. In this way, the type of VIV response and its evaluation can be assessed with simple calculations that use the parameters already present in codes and guidelines. An analytical solution of the original model allows straightforward evaluations inclusive of operative criteria to properly consider structural and flow conditions concerning the coefficients governing the VIV response in the spectral description, leaving out some assumptions that are commonly adopted. Extensive numerical applications, limited here to circular cylinders and including a real full-scale chimney, allow to identify the most significant parameters of the model and the criticalities connected with their choice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Wind Engineering and Industrial Aerodynamics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.