Abstract

Synchrotron X-ray radiography was utilized to study the time evolution of liquid water in an operating polymer electrolyte membrane (PEM) fuel cell. A high aspect ratio fuel cell designed with offset anode and cathode flow field channels was operated at conditions that produced critical water management issues. The X-ray beam was directed along the plane of the fuel cell, and was therefore employed to elucidate the through-plane distribution of liquid water in the porous materials. Due to the offset between the anode and cathode gas channels, the membrane electrode assembly exhibited sinusoidal warping, and liquid water accumulated in possible areas of delamination. Liquid water first appeared near the cathode catalyst layer, and then traveled laterally within the porous gas diffusion layer. The experiment provides a basis for future design considerations, including membrane thickness and attenuation estimates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.