Abstract

A method of using laser induced fluorescence(LIF)technique was applied to two-dimensional measurement of the liquid concentration distribution in the 250Y structured packing sheet. The experimental structured packing sheet was made of perspex so that the laser could pass through it. The visualization of the distribution of the liquid concentration in the structured packing sheet was realized. The calibration of the thickness and liquid concentration was carried out firstly and the regression formula I=kcd was acquired, in which concentration c and the liquid film thickness d were both considered. Then the liquid feed of uniform tracer(rhodamine)concentration entered the perspex structured packing from the top under different spraying densities. The corresponding thickness of liquid film on the packing was calculated. Finally, tracer(rhodamine)with a high concentration was injected only at one fixed point of the structured packing under different spraying densities of the liquid. With the known liquid film thickness, the concentration distribution of the tracer can be calculated inside the structured packing sheet.