Abstract

Reversible lasing performance degradation is investigated on an uncoated actively- biased GaAs/Al0.45Ga0.55As mid-infrared quantum cascade laser (MIR-QCL) facet. The surface temperature rises (ΔT) on the MIR QCL are characterized before and after the device undergoes an accelerated aging burn-in test, followed by hydrogen plasma treatment. The data is visualized by spatially resolved time-domain thermoreflectance (SR-TDTR) microscopy. On the laser facet, ΔT decreases with a drop in lasing performance and ΔT increases with an increase in lasing performance. Along the laser cavity, the thermal property change is negligible before and after the aging test, independent of the optical performance change. The results verify that thermal-induced facet oxidation is the main reason for the rapid degradation of the lasing performance in the early aging stage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.