Abstract

A study on the effects of image gray scale and pixel number on image quantification was performed analytically and experimentally in order to establish a method of measuring multiphase flows using neutron radiography. It was found from a simplified model that the resolution of an object thickness to be measured had logarithmic characteristics for the object thickness, and there is a possibility that the measured void fraction in high- and low-void-fraction regions might include large error. It was shown from the numerical analysis that the measurement error would be within 5% except for the annular flow region with the void fraction greater than 90%, when void fraction of an air-water two-phase flow in a channel with the local gap smaller than 9mm was measured under the condition of the image gray scale=100. It was revealed from a simplified model that the error due to the number of pixels would be within 5% when the number of pixels projecting the object is ten times greater than that projecting the object boundary.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.