Abstract
This paper presents the results of the flow boiling patterns and heat transfer coefficients of FC-72 in a small tube. The internal diameter of the tube is 0.48 mm, with a heated length of 73 mm. The mass flow rate varies from 50 to 3,000 kg/m2-s. The microtube is made of Pyrex in order to obtain the visualisation of the flow pattern along the heated channel. Different types of flow pattern have been observed: bubbly flow, deformed bubbly flow, bubbly/slug flow, slug flow, slug/annular flow, and annular flow. The experiments show the presence of flow instabilities in a large portion of the tests at low mass flow rates and low subcooling. Flow patterns in presence of flow instabilities are mainly characterized by bubbly/slug flow and slug/annular flow. Heat transfer rates have been studied in all flow pattern conditions. The two groups of results, with flow instabilities and without flow instabilities, show similar heat transfer behaviour. The heat transfer characteristics of the pipes have been studied in comparison with mass flux and vapour quality.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.