Abstract

In pioneering work, Senders (1983) tasked five participants to watch a bank of six dials, and found that glance rates and times glanced at dials increase linearly as a function of the frequency bandwidth of the dial's pointer. Senders did not record the angle of the pointers synchronously with eye movements, and so could not assess participants’ visual sampling behavior in regard to the pointer state. Because the study of Senders has been influential but never repeated, we replicated and extended it by assessing the relationship between visual sampling and pointer state, using modern eye-tracking equipment. Eye tracking was performed with 86 participants who watched seven 90-second videos, each video showing six dials with moving pointers. Participants had to press the spacebar when any of the six pointers crossed a threshold. Our results showed a close resemblance to Senders’ original results. Additionally, we found that participants did not behave in accordance with a periodic sampling model, but rather were conditional samplers, in that the probability of looking at a dial was contingent on pointer angle and velocity. Finally, we found that participants sampled more in agreement with Nyquist sampling when the high bandwidth dials were placed in the middle of the bank rather than at its outer edges. We observed results consistent with the saliency, effort, expectancy, and value model and conclude that human sampling of multidegree of freedom systems should not only be modeled in terms of bandwidth but also in terms of saliency and effort.