Abstract
To report visual outcomes in patients undergoing proton beam irradiation of tumors located within 1 disc diameter of the fovea. Retrospective review. Patients with choroidal melanoma involving the fovea treated with proton beam therapy between 1975 and2009. Three hundred fifty-one patients with choroidal melanomas located 1 disc diameter (DD) or less from the fovea and more than 1 DD away from the optic nerve were included in this study. In a subgroup of 203 of the patients with small and medium choroidal melanomas, the effect of a reduced dose of radiation, 50 Gy (relative biological effectiveness [RBE]) versus 70 Gy (RBE), on visual outcomes was analyzed. The Kaplan-Meier method and Cox regression analysis were performed to calculate cumulative rates of vision loss and to assess risk factors for vision loss, respectively. Visual acuity and radiation complications, which included radiation maculopathy, papillopathy, retinal detachment, and rubeosis, were assessed. Three hundred fifty-one patients were included in this study with a mean follow-up time of 68.7 months. More than one-third of patients (35.5%) retained 20/200 or better vision 5 years after proton beam irradiation. For those patients with a baseline visual acuity of 20/40 or better, 16.2% of patients retained this level of vision 5 years after proton beam irradiation. Tumor height less than 5 mm and baseline visual acuity 20/40 or better were associated significantly with a better visual outcome (P < 0.001). More than two-thirds (70.4%) of patients receiving 50 Gy (RBE) and nearly half (45.1%) of patients receiving 70 Gy (RBE) retained 20/200 or better vision 5 years after treatment, but this difference was not significant. Approximately 20% of patients with these smaller macular tumors retained 20/40 vision or better 5 years after irradiation. The results of this retrospective analysis demonstrate that despite receiving a full dose of radiation to the fovea, many patients with choroidal melanoma with foveal involvement maintain useful vision. A radiation dose reduction from 70 to 50 Gy (RBE) did not seem to increase the proportion of patients who retain usable vision.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.