Abstract

PurposeThis study investigates scintillation dosimetry coupled with Cherenkov imaging for in vivo dose monitoring during whole breast radiotherapy (WBRT). Given recent observations of excess dose to the contralateral breast (CB), in vivo dosimetry (IVD) could help ensure accurate dose delivery and decrease risks of secondary cancer. This work presents a rapid, streamlined alternative to traditional IVD, providing direct visualization of measurement location relative to the treatment field on the patient. Methods and Materials10 WBRT patients consented under an IRB-approved protocol were monitored with scintillation dosimetry and always-on Cherenkov imaging, on both their treated and CB for one to three fractions. Scintillator dosimeters, small plastic discs 1mm thick and 15mm in diameter, were calibrated against optically-stimulated luminescent dosimeters (OSLDs) to generate an integral output-to-dose conversion, where integral output is measured in post-processing through a custom fitting algorithm. The discs have been extensively characterized in a previous study for various treatment conditions including beam energy and treatment geometry. ResultsN=44 dosimetry measurements were evaluated, including 22 treated breast and 22 CB measurements. Following integral output-to-dose calibration, in vivo scintillator dosimeters exhibited high linearity (R2=0.99) with paired OSLD readings across all patients. The difference between scintillation and OSLD dose measurements averaged 2.8% of the prescribed dose, or an absolute dose difference of approximately 7 cGy. ConclusionsIntegration of scintillation dosimetry with Cherenkov imaging offers an accurate, rapid alternative for in vivo dose verification in WBRT, circumventing the limitations of conventional point dosimeters. The additional benefit of visualizing measurement locations relative to the treatment field provides users an enhanced understanding of results and allows for detection of high dose gradients. Future work will explore the applicability of this technique across a broader range of radiotherapy treatments, aiming to streamline IVD practices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.