Abstract
Visual acuity of 35 patients (49 eyes) implanted with AcrySoft®IQ PanOptix® spherical or toric lenses by Alcon was analyzed considering preoperative pupil size, angles alpha and kappa, the values of which were obtained in the examination using iTrace analyzer. Overall, no statistically significant changes in visual acuity were observed for changing values of the above parameters, except in the preoperative group with hyperopia, in which visual acuity to far distances improved with increasing pupil size. In some patients after refractive lens exchange, a slight deterioration in visual acuity to far distances was observed compared to preoperative values obtained with best correction; however, this did not have a significant impact on the level of patient satisfaction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.