Abstract

We have devised a new, simple and easy technique to measure the viscosity of hydrous silicate melts by combining an autoclave for melt hydration and the fiber elongation method for viscosity measurement. Using this, we measured the viscosity of hydrous rhyolitic melts whose water content ranges from 0.02 to 0.58 wt%. We observed a drastic decrease in viscosity against water content: 0.1 wt% water decreases the viscosity about an order of magnitude. Even when the water content is only 0.02 wt%, the viscosity decreased about half an order of magnitude. These results clearly demonstrate that the effect of water on viscosity should not be ignored even when it occurs as a trace constituent. We compared our experimental data with those derived from a non-Arrhenian viscosity model, which is considered to be applicable to calc-alkaline samples. This model succeeded in expressing the viscosity variation against water content but was unable to accurately predict the measured viscosity of liquids.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.