Abstract

This study evaluated the virucidal efficacy of acidic electrolyzed water (AEW) against African swine fever virus (ASFV) and avian influenza virus (AIV), according to the Animal and Plant Quarantine Agency (APQA) guidelines for efficacy testing of veterinary disinfectants. AEW (pH 5.0–6.5) was prepared using a commercially available “Electrolyzed Water Generator” with a free chlorine concentration (FCC) of 5–140 ppm, and its efficiency in reducing the titer of ASFV and AIV was tested in a suspension under low- and high-level organic soiling. Under low-level organic soiling conditions, AEW with FCC ≥40 ppm was effective against ASFV; under high-level organic soiling conditions, AEW with FCC ≥80 ppm was effective against ASFV. Under low-level organic soiling conditions, AEW with FCC ≥60 ppm was effective against AIV; under high-level organic soiling conditions, AEW with FCC ≥100 ppm was effective against AIV. The virucidal effect of AEW seemed dependent on the FCC and the presence of organic soiling. Based on these data, we recommend the following minimum FCCs in AEW treatment for routine disinfection in veterinary field under low- and high-level organic soiling conditions: for ASFV, 50 ppm and 100 ppm; and for AIV, 75 ppm and 125 ppm, respectively. In conclusion, the virucidal effects of AEW against ASFV and AIV emphasize its potential utility as a disinfectant, and we suggest considering organic soiling conditions while using AEW for implementing effective control measures for field applications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call