Abstract

PurposeVivid Vision Perimetry (VVP; Vivid Vision, Inc) is a novel method for performing in-office and home-based visual field assessment using a virtual reality platform and oculokinetic perimetry. Here we examine the reproducibility of VVP Swift and compare results with conventional standard automated perimetry (SAP) and spectral-domain (SD) OCT.DesignCross-sectional study.ParticipantsFourteen eyes of 7 patients with open-angle glaucoma (OAG) (average age, 64.6 years; 29% women) and 10 eyes of 5 patients with suspected glaucoma (average age, 61.8 years; 40% women) were enrolled.MethodsPatients with OAG and suspected glaucoma were enrolled prospectively and underwent 2 VVP Swift examinations. Results were compared with 1 conventional SAP examination (Humphrey Visual Field [HVF]; Zeiss) and 1 SD OCT examination.Main Outcome MeasuresMean sensitivity (in decibels) obtained for each eye in 2 VVP Swift test sessions and a conventional SAP examination, thickness of the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) for the SD OCT examination, and mean test durations of the VVP Swift and SAP examinations.ResultsThe mean test duration of VVP Swift in both eyes (8.5 minutes) was significantly shorter (P < 0.001) than SAP (12.2 minutes). The average absolute difference of the mean sensitivity between the 2 VVP Swift sessions was found to be 0.73 dB (95% confidence interval [CI], 0.40–1.06). A statistically significant association was found between average mean sensitivity measurements from the VVP and mean deviation (MD) measurements obtained by the HVF with a Pearson correlation coefficient of 0.86 (95% CI, 0.70–0.94; P < 0.001). Mean visual sensitivity measurements from the VVP Swift test were significantly associated with average RNFL thickness (r = 0.66; P = 0.014) and GCC thickness (r = 0.63; P = 0.02), whereas the correlation coefficients between HVF MD and RNFL and GCC were 0.86 (P < 0.001) and 0.83 (P < 0.001), respectively.ConclusionsOur results demonstrated that the VVP Swift test can generate reproducible results and is comparable with conventional SAP. This suggests that the device can be used by clinicians to assess visual function in glaucoma.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.