Abstract

Background: Hardness could found to be sensitive to the residual monomer content in the polymerized resins; the hardness is an effective method to evaluate the polymerization depth of resin materials. In addition, hardness had used to predict the wear resistance of dental materials. Materials and Methods: Acrylic resin specimens had divided into two groups according to the type of material tested (group I: conventional heat cured acrylic resin, group II: resin impregnated fiberglass reinforced complete denture base). Vicker`s micro hardness tester was used to measure Vicker`s hardness number (VH) of the acrylic specimens in which diamond indenter was applied under 25 g load for 10 seconds time evaluated by 20 x objective lens. Results: The VH values of resin impregnated fiberglass reinforced acrylic resin showed statistically insignificant lower values (as P < 0.05) than conventional heat cured acrylic resin. Conclusion: Unreacted monomer would act as a plasticizer and weaken the matrix. Heat cured PMMA could perform better in this aspect that the residual monomer content was less when compared to PMMA reinforced through other mechanisms. Key words: Hardness, Fiber, Reinforce, Denture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.