AbstractVibration has become a serious serviceability problem due to the large openings of girder, lightweight floor systems, and high-strength materials used in practice. The results from both heel-drop and jumping floor vibration tests of a large-span prestressed cable RC truss (PCT) floor system are presented. System parameters such as peak acceleration, fundamental frequency, and damping ratios were considered and studied. The results and comparisons were taken based on the on-site test data. The comparison results indicate inconsistencies with the heel-drop or jumping impact models proposed by other researchers. The results from heel-drop and jumping tests were comprehensively compared against published codes. Based on the classic plate theory, a derived accurate formula for a PCT floor system is proposed. Lastly, a simplified method is suggested, which uses the constant moment of inertia for the cross section of a PCT girder.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.