Abstract
A new, world-class performing arts center is currently being developed in a metropolitan center in the United States. The center will include two grand performance theaters. One of these theaters will be located close to a busy surface street. Vibration measurements conducted at the undeveloped site indicated that groundborne noise from street traffic would be audible within the completed theater unless measures were incorporated into the design to reduce vibration transmitted from the street to the interior of the theater. This will be achieved by structurally separating the performance area of the theater from the surrounding structure by supporting the theater on custom designed, resilient bearing pads. This paper discusses the vibration measurements taken, the projections of groundborne noise and the vibration mitigation measures that were incorporated into the structural design of the theater building to reduce groundborne noise to meet the project design criteria for background noise.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.