Abstract

We propose and realize a modified spectral-domain interferometer to measure the physical thickness profile and group refractive index distribution of a large glass substrate simultaneously. The optical layout was modified based on a Mach-Zehnder type interferometer, which was specially adopted to be insensitive to mechanical vibration. According to the measurement results of repeated experiments at a length of 820 mm along the horizontal axis, the standard deviations of the physical thickness and group refractive index were calculated to be 0.173 μm and 3.4 × 10(-4), respectively. To verify the insensitivity to vibration, the physical thickness values were monitored at a stationary point while the glass panel was swung at an amplitude exceeding 20 mm. The uncertainty components were evaluated, and the combined measurement uncertainty became 161 nm (k = 1) for a glass panel with a nominal thickness of 0.7 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.