Abstract
PZT bimorph actuator is used to design mini-sized vibratory feeder applied in the micro-medical industry. Since the vibration trajectory of PZT bimorph actuator will be controlled to obtain desired parts feeding, optical positioning sensor is used to provide non-contact measurement with precise displacement. Because the torsional vibration causes the rotary motion of the actuator, the angle between the optical sensor and the PZT plate is subjected to change during the vibration procedure. Optical loss due to a varying reflection angle is compensated by multiple-segment micrometer calibration. Satisfactory hysteresis suppression and good waveform tracking is obtained with implementation of optical sensor in piezo-actuating system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.