Abstract

This paper presents a novel active resonant vibration control experiment of a flexible clamped-clamped plate using an improved filtered-U least mean square (FULMS) algorithm and laser displacement measurement. Different from the widely used PZT sensors or acceleration transducers, the vibration of the flexible clamped-clamped plate is measured by a non-contact laser displacement measurement sensor with higher measurement accuracy and without additional load to the plate. The conventional FULMS algorithm often uses fixed step size and needs reference signal related to the external disturbance signal. However, the fixed step size method cannot obtain a fast convergence speed and it will result in a low residual error. Thus, a variable step size method is investigated. In addition, it is difficult to extract reference signal related to the vibration source directly in the practical application. Therefore, it is practically useful that a reference signal is constructed by both the controller parameters and the vibration residual signal. The experimental results demonstrate that the improved FULMS algorithm has better vibration control effect than the proportional derivative (PD) feedback control algorithm and the fixed step-size control algorithm.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call