Abstract
AbstractIn this paper, we consider a vibration suppression problem for a pneumatic isolation table with on–off valves using the feedforward control input profile. In this system, it is possible to enhance the vibration suppression performance by adjusting the flow rate of air into and from air springs. However, there is a significant problem that a steady‐state deviation, namely an offset, for displacement of the table occurs. Therefore, we propose an efficient search method of the optimal feedforward control input profile, which provides high vibration suppression performance without a steady‐state deviation. A key idea is to update the control input profile to belong to a space where velocity of the table does not change.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.