Abstract

Currently ultrasonic wire bonders with precision capillary tips are widely used in the packaging industry for bonding wires to ICs and circuits. However, the quality and strength of a bond are affected significantly by the vibration of the bonding capillary. It is, therefore, necessary to study the vibration characteristics of the capillary for better understanding and for developing a non-perturbative and low-cost monitoring device for improving bonding quality control. In this paper, the vibration characteristics of the capillary are presented in terms of natural frequency and vibration modes using finite-element models. The predicted displacement profile along the capillary is compared with the measurement using a non-contact laser interferometer. In general, a good agreement between the prediction and measurement is obtained, and it shows that the interferometer may be a good monitoring tool for characterization of capillary tip vibration, as well as providing a reference for other monitoring devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.