Abstract

This paper considers a practical structure-borne sound source characterization for mechanical installations, which are connected to plate-like structures. It describes a laboratory-based measurement procedure, which will yield single values of source strength in a form transferable to a prediction of the structure-borne sound power generated in the installed condition. It is confirmed that two source quantities are required, corresponding to the source activity and mobility. For the source activity, a high-mobility reception plate method is proposed which yields a single value in the form of the sum of the squared free velocities, over the contact points. A low-mobility reception plate method also is proposed which, in conjunction with the above, yields the source mobility in the form of the average magnitude of the effective mobility, again over the contact points. Experimental case studies are described and the applicability of the laboratory data for prediction and limitations of the approach are discussed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call