Intravenous vesicants are commonly infused via peripheral intravenous catheters (PIVC) despite guidelines recommending administration via central route. The impact of these medications on PIVC failure is unclear. We aimed to assess dose-related impact of these caustic medications on ultrasound-guided (US) PIVC survivorship. We performed a secondary analysis of a randomized control trial that compared survival of two catheters: a standard long (SL) and an ultra-long (UL) US PIVC. This study involved reviewing and recording all vesicants infusions through the PIVCs. Type and number of vesicants doses were extracted and characterized as one, two or multiple. The most commonly used vesicants were individually categorized for further analysis. The primary outcome was PIVC failure accounting for use and timing of vesicant infusates. Between October 2018 and March 2019, 257 subjects were randomized with 131 in the UL group and 126 in the SL group. Vesicants were infused in 96 (37.4%) out of 257 study participants. In multivariable time-dependent extended Cox regression analysis, there was no significant increased risk of failure due to vesicant use [adjusted hazard ratio, aHR 1.71 (95% CI 0.76-1.81) p = 0.477]. The number of vesicant doses was not significantly associated with the increased risk of PIVC failure [(1 vs 0) aHR 1.20 (95% CI 0.71-2.02) p = 0.500], [(2 vs 0) aHR 1.51 (95% CI 0.67-3.43) p = 0.320] and [(≥ 3 vs 0) aHR 0.98 (95% CI 0.50-1.92) p = 0.952]. Vesicant usage did not significantly increase the risk of PIVC failure even when multiple doses were needed in this investigation. Ultrasound-guided PIVCs represent a pragmatic option when vesicant therapy is anticipated. Nevertheless, it is notable that overall PIVC failure rates remain high and other safety events related to vesicant use should be considered when clinicians make vascular access decisions for patients.

Highlights

  • With over 300 million used annually in the United States, peripheral intravenous catheters (PIVC) are the most commonly used invasive device in the acute care setting [1,2]

  • In multivariable time-dependent extended Cox regression analysis, there was no significant increased risk of failure due to vesicant use [adjusted hazard ratio, aHR 1.71 p = 0.477]

  • The number of vesicant doses was not significantly associated with the increased risk of PIVC failure [(1 vs 0) aHR 1.20 p = 0.500], [(2 vs 0) aHR 1.51 p = 0.320] and [( 3 vs 0) aHR 0.98 p = 0.952]

Read more

Summary

Introduction

With over 300 million used annually in the United States, peripheral intravenous catheters (PIVC) are the most commonly used invasive device in the acute care setting [1,2]. The Infusion Nursing Society (INS) created this list based on infusate osmolarity thresholds that increase the likelihood of these complications [13]. These medications can cause local reactions at the level of the vein precipitating vein wall injury, inflammation, thrombus formation, extravasation into the surrounding tissue and potentially lead to tissue necrosis. Premature catheter failure at a minimum is a likely consequence but patients may require additional therapies and even surgical intervention for treatment [14]. Intravenous vesicants are commonly infused via peripheral intravenous catheters (PIVC) despite guidelines recommending administration via central route. The impact of these medications on PIVC failure is unclear. We aimed to assess dose-related impact of these caustic medications on ultrasound-guided (US) PIVC survivorship

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.