Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Patients with a drug-induced Brugada electrocardiogram (ECG) are thought to have a lower risk of sudden cardiac death than those with a spontaneous type 1 ECG. Despite having a Brugada ECG, most patients do not need an implantable cardioverter defibrillator (ICD). Purpose To report a district general hospital experience on referral and outcomes of ajmaline challenge (AC) with medium term follow up. Methods 92 consecutive patients (50 males, mean age 41 ±17) had an AC in a single centre from 2014-2021. High ventricular leads were used from 2015. Ajmaline (1m/kg) was administered intravenously over 10-minutes. Data were collected from the electronic health record. Results The AC was positive in 18 (20%) patients. The yield from high leads was higher (7% vs 22%) p=0.28) but not statistically significant. There were no deaths or documented ventricular arrhythmias (VA) in AC positive patients during a median follow up of 3.2 years (1.7-4.9). The resting ECG was normal in 46.7%. A type 1 pattern had been provoked by fever or electrolyte derangements in 3.3%, type 2 pattern in 8.7% and a type 3 pattern in 5.4%. An RSR pattern (not in keeping with a BrS ECG) was seen in 26.4%. The test was stopped prematurely due to QRS widening >150ms in 1 patient. No adverse arrhythmic events occurred (table 1). In our cohort, positive AC patients were older (48y vs 37y p= 0.05) and more likely to have a type 2 (28% vs 4% p=0.007) or type 3 ECG (17% vs 3% p=0.05). Asymptomatic patients were more likely to have a normal ECG (22% vs 78% p=0.05) Of those with a positive AC, nine patients had symptoms of palpitations or syncope (table 2). A subcutaneous ICD (S-ICD) was implanted for syncope in two patients. No device therapies have occurred during a follow up of 2.5 years and 3.9 years respectively. Of those with a positive AC but asymptomatic, one S-ICD was initially implanted due to patient preference. A second S-ICD was implanted in a patient who experienced a collapse and brief seizure in the context of modest alcohol consumption. In seven positive patients (39%) and 18 negative patients (23%) an ILR was implanted. 1 episode of complete heart block was detected in an ajmaline negative patient during a median follow up of 2.7 years (1.7-3.9). There were no device related complications or adverse events. Conclusion AC is safe with a low number of device implants and ICD shocks. The yield from ILR implants was very low. A single patient had a potentially adverse outcome after consuming alcohol, a known trigger for VA in BrS. Our findings are in keeping with contemporary evidence that suggests the risk of adverse cardiac events in drug-induced BrS is low. However, time to first ICD shock may occur after ten years or more from diagnosis so long term follow up is required.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.