Abstract

High frequency fatigue tests were carried out with a 20 kHz ultrasonic testing facility to investigate the cyclic deformation behavior of Ti6Al4V in the Very High Cycle Fatigue (VHCF) regime in detail. The S,Nf -curve at the stress ratio R = -1 shows a significant decrease of the stress amplitude and a change from surface to subsurface failures in the VHCF regime for more than 107 cycles. Microscopic investigations of the distribution of the α-and β-phase of Ti6Al4V indicate that inhomogeneities in the phase distribution are reasons for the internal crack initiation. Scanning electron microscopy as well as light microscopy were used to investigate the internal crack initiation phenomenon in the VHCF-regime. Beside the primary fatigue crack additional defects like micro cracks and crack clusters were observed in the fatigued specimens. SEM-investigations of specimens which were loaded up to 1010 cycles without failure show irreversible microstructural changes inside the specimens. Two step tests were performed to evaluate the influence of internal fatigue induced defects observed in specimens which did not fail within 1010 cycles.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.