Abstract

Abstract Permanent magnet motor drive is a widely used technology, offering many advantages, such as exceptional speed, torque control and greater flexibility. Improvement of reliability and efficiency has become a great research interest. Towards this direction and taking into account the major developments in permanent machine technology over the recent years, the use of energy recovery converters has been introduced in various industrial applications. In this paper, the effects of harmonics on a three-phase motor controlled by a drive are analysed, and the behaviours of the filter topology after adopting regenerative drives are studied. The main contribution of this study is a methodology to foresee the standards that can be achieved with the use of an active front end system topology with filters. Moreover, the use of an optimum filter that eases the power system distortion is presented. The analysis presented in this paper is validated experimentally.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.