Abstract

This paper explores the relationship between the Vertical Sky Component (VSC) metric and the European and Swedish daylighting regulations. VSC, a static geometrical metric, is considered a useful early indicator of indoor daylighting, as it is insensitive to late-stage design details such as material properties and internal layout. However, its relationship with modern building daylighting legislation has not been established. To address this gap, the paper investigates the relationship of VSC and daylight compliance by static and dynamic methods through simulations of a ‘shoebox’ room with varying Window-to-Floor Ratios (WFRs) and external obstruction dimensions. The results demonstrate that VSC has a large effect on daylighting compliance and can be a useful early planning tool. The study concludes that using VSC as a daylighting indicator in the urban planning process can lead to improved early design routines for better daylight compliance in the late design stages. Future work should aim to establish VSC performance thresholds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.