Abstract

AbstractThis paper reports the results of a numerical parametric study focused on the prediction of vertical load distribution and vertical gap compression between precast concrete facing panel units in steel-reinforced soil walls ranging in height from 6 to 24 m. The vertical compression was accommodated by polymeric bearing pads placed at the horizontal joints between panels during construction. This paper demonstrates how gap compression and magnitude of vertical load transmitted between horizontal joints are influenced by joint location along the height of the wall, joint compressibility, and backfill and foundation soil stiffness. The summary plots in this study can be used to estimate the number and type (stiffness) of the bearing pads to ensure a target minimum gap thickness at the end of construction, to demonstrate the relative influence of wall height and different material component properties on vertical load levels and gap compression, or as a benchmark to test numerical models used for proje...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.