Abstract
Measurements of SO 2 and NO 2 were conducted from January to March 2001 and August 2003 at a 325 m meteorological tower in Beijing. The concentrations of SO 2 and NO 2 observed by passive samplers at ten heights showed complex vertical distributions in winter and summer. The vertical profiles of pollutants were influenced by source emissions, meteorological conditions, urban canopy and other factors. The comparison analysis of winter and summer pollutant concentrations suggests that the decrease in SO 2 concentration was significant in summer, and the reduction of NO 2 was relatively not distinctive. Domestic heating and industrial sources were major sources of SO 2 in urban areas of Beijing. Differing from SO 2, urban NO 2 was closely related to traffic emission. Meteorological evidence suggests that strong temperature inversions influence vertical distribution of air pollutants over urban Beijing. The high levels of SO 2 and NO 2 concentrations were due to the accumulation of pollutants resulting from the stable atmosphere prevalent during the measurement period. The vertical distributions of air pollutants were controlled and affected by atmospheric dynamical characteristics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.