Abstract
This paper summarises the preliminary results of the electromagnetic (EM) analyses for ITER vacuum vessel and in-vessel components, such as blanket and divertor modules. Two disruption scenarios are taken into account: plasma centered disruption, and vertical displacement event (VDE). Eddy currents and forces due to VDE/disruption were calculated using the 3D shell element code TYPHOON and the 3D solid element code EMAS and ANSYS. The plasma motion and current decay used in the EM analysis has been supplied by 2D axisymmetric plasma equilibrium codes, MAXFEA. The EM loads in the blanket module are reduced by deep poloidal and radial slits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.