Abstract

This study investigated the vertebral bone quality (VBQ) score as a potential tool for opportunistic osteoporosis screening and its correlation with dual-energy X-ray absorptiometry (DXA) values. In a single-center retrospective cohort of 130 patients, VBQ and DXA measures were compared using various statistical analyses. The optimal VBQ threshold for predicting osteoporosis was determined using receiver operating characteristic (ROC) analysis. VBQ exhibited a significant negative association with DXA values, suggesting that higher VBQ scores are indicative of lower bone density. Age and VBQ were significant predictors of osteoporosis, with both increasing the log-odds of the condition. An optimal VBQ threshold of 2.7 was determined, demonstrating fair discriminatory power and high negative predictive value. The study highlighted the potential of VBQ as a diagnostic tool for osteoporosis with high intra- and inter-observer reliability. The optimal VBQ threshold of 2.7 can aid in ruling out osteoporosis and identifying individuals for further evaluation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.