Abstract

Vertebral artery dissections (VAD) are known to occur as a result of mechanical manipulations of the cervical region, traumatic injury, iatrogenic injury and are also known to arise spontaneously. We report a case of vertebral artery dissection following vertebral artery cannulation during a central line placement and review the literature. The patient underwent intravascular catheter placement that subsequently demonstrated arterial blood. Duplex ultrasound and computed tomographic (CT) scan confirmed vertebral artery cannulation. The catheter was removed at the bedside with pressure, and a subsequent duplex ultrasound scan revealed a vertebral artery dissection. There were no neurological sequelae. The patient was successfully anticoagulated with warfarin but died from unrelated complications. This case report describes the rare iatrogenic event of VAD and reviews its etiology, diagnosis, complications, and management.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.