Abstract

The construction of a low power cryocooler consisting of a five-stage plastic Stirling cooler with an additional Joule-Thomson stage is described. Among its novel features are a contamination-free, pneumatic helium compressor and displacer drive. Valve timing is under computer control. Titanium foil embedded in the cylinder wall reduces helium diffusion through the plastic. The Joule-Thomson stage uses the same low pressure helium as the Stirling stages. The Stirling system cools down below 9 K. The Joule-Thomson stage delivers a few mW cooling at 4.2 K.