Abstract

In a seismic design, the dynamic loads are generally dependent on the inertial interaction caused by earthquake. But for the foundations embedded in soil, the dynamic loads are influenced by both the inertial and kinematic interactions among superstructure, foundation and soil. Especially, when a foundation is embedded in soft surface ground, the effects due to the kinematic interaction increase and should be considered in seismic design. For this reason, a method called seismic deformation method (SDM), which is suitable for an intensive earthquake motion (level 2 earthquake motion), has been stipulated recently in a new design code called Seismic Design Code for railway structures (the Railway Code, drawn up by Railway Technical Research Institute, Japan, 1999) [Railway Technical Research Institute. Seismic Design Code for railway structures. Tokyo: Maruzen; 1999]. In order to grasp the suitability of the SDM to actual structures, pile foundations, which experienced the Hyogoken-Nanbu earthquake, were taken as the objects for investigations. Comparison studies between the SDM analysis and reconnaissance were conducted. As a result, the adequacy of the SDM to actual foundations was confirmed to prove good agreement between the two results from the viewpoint of engineering practice. In addition, determination of indices for seismic-performance evaluation and speculation of damage mechanism of the foundations are also discussed in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call