Abstract
In a differential transmission line, a large common-mode current is excited due to its asymmetry. In this paper, the authors demonstrate experimentally the common-mode current and verify the imbalance difference model that was proposed for prediction of the common-mode current reduction. Experimental results show that the reduction of common-mode current of about 20 dB is achieved by changing the position of the transmission line. In addition, the differences that are calculated using the imbalance difference model are in agreement with the measured ones within 2 dB.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.