Verification condition generators (VCGs) can reduce overall correctness statements about sequential programs to verification conditions (VCs) that can then be proved independently by automatic theorem provers like SMT solvers. SMT solvers became not only more powerful in recent years in that they can now solve much bigger problems than before, they can now also solve problems of less restricted logics, for example, by covering non-linear arithmetic as required by some hybrid systems. However, there is so far still no VCG procedure that could generate VCs of hybrid programs for these SMT solvers. We therefore propose in this paper a first VCG procedure for hybrid systems that is based on induction proofs on the strongly connected components (SCCs) of the underlying state transition diagrams. Given the right invariants for a safety property, the VCs can be automatically generated for the considered hybrid system. The validity of the VCs is then independently proved by SMT solvers and implies the correctness of the considered safety property.