This paper presents procedures and techniques for correcting the linear optics of the VEPP-4M collider. The accelerator structure investigation is based on the measurement and analysis of orbit response matrices (ORM) and optical functions reconstructed from turn-by-turn (TbT) data. Having no technical description of quadrupole lenses and corrector magnets, we have calibrated their current dependencies of magnetic strengths and fields, respectively. Corresponding to the reference orbit, quadrupole shifts in each plane have been obtained by using the beam-based alignment (BBA) technique. The accelerator optics has been corrected and calibrated at the injection energy of 1.9 GeV. The software combining automated optical functions measurement and correction has been developed and successfully implemented at VEPP-4M.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.