Abstract

Continuous electrocardiographic (ECG) monitoring is used to identify ventricular tachycardia (VT), but false alarms occur frequently. The purpose of this study was to assess the rate of 30-day in-hospital mortality associated with VT alerts generated from bedside ECG monitors to those from a new algorithm among intensive care unit (ICU) patients. We conducted a retrospective cohort study in consecutive adult ICU patients at an urban academic medical center and compared current bedside monitor VT alerts, VT alerts from a new-unannotated algorithm, and true-annotated VT. We used survival analysis to explore the association between VT alerts and mortality. We included 5679 ICU admissions (mean age 58 ± 17 years; 48% women), 503 (8.9%) experienced 30-day in-hospital mortality. A total of 30.1% had at least 1 current bedside monitor VT alert, 14.3% had a new-unannotated algorithm VT alert, and 11.6% had true-annotated VT. Bedside monitor VT alert was not associated with increased rate of 30-day mortality (adjusted hazard ratio [aHR] 1.06; 95% confidence interval [CI] 0.88-1.27), but there was an association for VT alerts from our new-unannotated algorithm (aHR 1.38; 95% CI 1.12-1.69) and true-annotated VT(aHR 1.39; 95% CI 1.12-1.73). Unannotated and annotated-true VT were associated with increased rate of 30-day in-hospital mortality, whereas current bedside monitor VT was not. Our new algorithm may accurately identify high-risk VT; however, prospective validation is needed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call