Capillary ultramicroelectrodes were inserted into ventricular muscle fibers of dogs in ventricular fibrillation and action potentials obtained were compared with deflections of unipolar direct lead, adjoining bipolar direct lead or other electrocardiograms taken simultaneously. In most stages of ventricular fibrillation neither synehronism nor any other regular time relationship could he found between them. Microelectrodes inserted at two points variously distant on various regions of the ventricular surface also failed to show any regular time relationship. Total incoordination of ventricular muscle fibers was thus supported.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.